Need more power points, fewer worries, and a trusted team to make it happen? HEP is Lancing’s go-to specialist for safe, code-compliant electrical outlets that look as good as they perform. From kitchens demanding durable, splash-proof sockets to home offices craving fast-charge USB ports, we design, supply, and install solutions that fit your lifestyle and your dĆ©cor. Every outlet is tested, labelled, and documented, so you always know which breaker protects which device—no guessing, no surprises.

Our NICEIC-approved electricians arrive on time, protect your floors and furniture, and tidy up before they leave. We use only quality components, back them with solid warranties, and explain exactly how to keep your new electrical outlets working flawlessly for years to come. Whether you’re upgrading a single room or rewiring an entire property, choose HEP and plug into the peace of mind Lancing homeowners and businesses deserve.

FAQs

Do I need a qualified electrician to install or replace electrical outlets in my Lancing home?

Yes. In the UK, any alteration to fixed electrical wiring—including adding or replacing outlets—must comply with BS 7671 (IET Wiring Regulations) and, in many cases, Part P of the Building Regulations. Using a registered electrician in Lancing ensures the work is certified, notifies Building Control where required, maintains your home insurance validity, and guarantees that the outlet is installed safely with the correct cable size, RCD protection and earthing arrangements.

What safety features should modern outlets have?

Modern UK outlets incorporate several safety features: (1) Integrated shutter mechanisms that prevent foreign objects entering live and neutral pins unless the earth pin is inserted; (2) mandatory RCD protection on virtually all domestic socket circuits, offering rapid disconnection (≤ 40 ms) if a fault is detected; (3) tamper-resistant or lockable faceplates for child safety; (4) built-in USB ports with current-limit circuitry on some models; and (5) high-integrity earth pathways to protect users in the event of a fault.

How often should electrical outlets be tested or inspected?

For owner-occupied homes, a formal Electrical Installation Condition Report (EICR) is recommended every 10 years, or at the point of property sale or major renovation. Rental properties in England—including Lancing—must have an EICR at least every 5 years. In between EICRs, check outlets visually for heat damage, cracks or loose fixings, and test RCDs every six months by pressing the ā€˜T’ or ā€˜Test’ button. Any signs of deterioration or tripping issues warrant prompt inspection by a qualified electrician.

Can I add USB charging outlets without rewiring my entire house?

Usually yes. USB or USB-C outlets are designed to retrofit into a standard 25–35 mm back box. Provided the existing wiring is in good condition, an electrician can swap the faceplate for a combined 13 A socket with integrated 5 V USB modules. The electrician will test that the circuit has RCD protection and adequate earth continuity, then issue a Minor Electrical Installation Works Certificate (MEIWC). No full rewire or Building Control notification is typically required for a like-for-like replacement.

Why does my outlet keep tripping the RCD, and what should I do?

Frequent RCD trips point to a leakage fault on the circuit, which could stem from water ingress, damaged appliance flexes, overstressed extension leads or deteriorated wiring insulation. First unplug all appliances, reset the RCD, then reconnect devices one by one to isolate the culprit. If the RCD still trips with nothing connected, the fault is in the fixed wiring or the socket itself. Do not bypass or replace the RCD; instead, call a qualified Lancing electrician to carry out insulation-resistance tests and pinpoint the problem safely.

What is the typical cost of installing additional outlets in Lancing, and how long does it take?

Costs vary with wall construction and circuit access, but as a guide: adding a single surface-mounted socket on an existing ring final circuit starts at Ā£80–£120; a flush-mounted double socket with chasing and making good is usually Ā£120–£180; and a new radial circuit from the consumer unit can range from Ā£250–£500 depending on distance and number of points. Most single additions are completed in 1–2 hours; a new circuit may take a full day. Always request a written, itemised quote that includes testing and certification.